Quantaflex ELTM  Design Guide

Physical Characteristics

Minimum Borders Required

Borders

A) Bus Bars
On those edges where a Bus Bar is required there is a minimum border from the edge of the part to the beginning of lit area of 0.090" (2.2 mm)

B) Edges/Cutouts
On those edges where no bus bar is required and on all internal cutouts, there is a minimum border from the edge of the part to the beginning of lit area of 0.045" (1.1 mm).

Not much of an edge needed

C) Clear Areas
When it is required that an area internal to the lit area be clear, there is a minimum border from the edge of the clear area to the beginning of lit area of: 0.025" (0.6 mm). This type of design is used most commonly when an E.L./LED combination is used. The required clear areas must be specified on all prints.

D) Exceptions
MKS makes every effort to meet the needs and requirements of your particular design. Please consult with our technical representatives if there are any questions regarding dimensional tolerances or borders.