Operating Voltage
60 - 120 V AC RMS Recommended for most applications
40 - 200 V AC RMS (Min. - max.)
Sine Wave is preferredIf you have a design requirement which is outside of the recommended range, please contact one of our representatives for additional information.
Within the normal operating range of an EL lamp, the brightness is approximately proportional to the square of the RMS Voltage. Therefore, a doubling of RMS voltage will increase the brightness of the lamp by approximately four times.